beautypg.com

Gateway E-826R User Manual

Page 81

background image

CHAPTER 5: Troubleshooting your Autoloader

www.gateway.com

76

Error code field descriptions

Field

Description

Recovery Action

Defines what the autoloader does, based on the event that occurred.

If the value is 0, the autoloader will continue operations because this is
typically a soft, recoverable event, or an event that is just recording an
action.

If the value is other than 0, then you must reboot the autoloader in order
to recover from the event. The reboot happens automatically.

Task ID:

Defines what firmware task was being performed at the time of the event. This ID is presented

in Hex format.

00

System Timer

01

Loader Manager

02

Picker

03

Magazine Left

04

Magazine Right

07

Drive Manager

08

Bar Code Reader

09

Front Panel

0A

IP

0B

Diagnostic

0C

Error

0D

Code Update

0E

ADI

0F

Drive Manager Timer

11

HTTP

12

SNTP

13

SCSI

14

SPI

20

Idle

3E

Watch Dog

3F

Un-handle Interrupt

Error:

Defines the type of error or event that did occur. Follow the suggested actions to troubleshoot each

type of error.

Software Location ID:

Defines a location in the firmware internal to the task being performed. This

ID is used by firmware engineering to identify what part of the actual firmware task detected the event.

This manual is related to the following products: