Installation in a .280 Diameter thru-hole rack
To install the rail in a .280 diameter thru-hole rack:
1
Identify the correct mounting holes on the vertical rail, making sure that
the selected holes are on the same level.
2
Mount the front cover plate to the vertical rail in the identified holes by
using M6 (.200”) threaded bolts in the center two holes of the plate.
Important
The upper and lower tabs of the inside
plate do not enter the holes of the rack.
They deform when secured.
3
Install the chassis into the rack by aligning the chassis-mounted rails with
the mounted rail assemblies, then pushing the chassis into the rack.
4
Secure the chassis into the rack by bolting the autoloader tabs to the
upper and lower holes in the front cover plate using M6 (.200”) threaded
bolts.
Front cover
plate
10-32 inside
nut plate
Rail
assembly
Vertical rail
Autoloader tab
(autoloader not
shown)