Because of the high amperage draw from this
machine, we recommend that you hardwire it
directly to your circuit breaker and install a lock-
ing power disconnect lever near the machine.
see
page 12 for wiring recommendations.
if you have performed all of the previous set up
instructions, you are ready to connect the resaw
to the power source.
Tools Needed
Qty
phillips head screwdriver ................................ 1
Hardware Needed
Qty
Conduit (not included) .............................. Varies
power wires (not included) ...................... Varies
To connect the resaw to the power source:
1. read through Section 2: Circuit Requirements
on
page 12 to double-check that your setup
follows the safety and circuit requirements.
note—When using a phase converter, the power
from the manufactured power leg (sometimes
called the wild wire) can fluxuate. Connect the
manufactured power leg to the S terminal to pre-
vent damage to the transformer. The wire from the
S terminal can handle some fluxuation because it
goes directly to the motor. The power going to the
R and T terminals goes to the transformer and
must be consistent to prevent damage.
figure 23. Main terminal.
3. Close and latch the electrical panel on the
machine.
4. Shut off the main power at the power
source circuit breaker.
5. Connect the conduit to the shut off lever box
and the bottom of the electrical panel.
6. install the power wires to the disconnect
switch.
connecting to
power
2. Connect the power wires to the main termi-
nal shown in
figure 23.