B01[******]d1 – Fostex D-160 User Manual
Page 115
D-160 Owner's Manual (Saving and loading data)
115
B01[******]D1
(****** = current title, D1 = Disk-1)
Rotating the JOG dial will toggle between “B01” and “Eject.”
If you wish to cancel the load operation and remove the disk, select “Eject” and press the EXECUTE/
YES key.
4. While “B01[******]D1 appears on the display, press the EXECUTE/YES key. (“SURE?” flashes).
The current Program number flashes and you can select the load destination Program.
P01[******
(****** = current title)
5. Use the JOG dial to select a Program into which to load data. (“SURE?” flashes.)
If you select a Program that already contains data and execute the load operation, that existing
data will be overwritten by the new data. If you do not wish to overwrite data in the Program, use
the JOG dial to select “New PGM” to execute the load operation.
6. Press the EXECUTE/YES key. (“REMAIN” and “LOAD” light up.)
Load operation will start, and the D-160 will display “B01>>P01 -***MB.”
This means that Backup 1 (B01) data in the SCSI disk is being loaded into Program 1 (P01) on the
internal hard disk. As the operation progresses, the number “-***MB” (remaining data amount to
be loaded) will count down. When loading from the first disk is complete, the message “Insert
Disk2” appears and the first disk is automatically ejected.
7. Insert the second disk into the SCSI device.
Loading from the second disk automatically starts. The display and count down are the same as
those for the first disk.
After all data is loaded, “COMPLETED!” lights up, and Time Base of the destination Program will
be located. Press the STOP button or the EXIT/NO key, and “COMPLETED!” will turn off.
If an error occurs during execution of load and "Error 36" appears in the display, carry out
the following steps:
1
1
1
1
1
. Press the EXIT/NO key.
"Retry?" will appear in the display.
2
2
2
2
2
. If load is to be executed again, press the EXECUTE/YES key upon display of "Retry?."
Load will be executed again.
If ALL load was carried out in this process, load will be executed again from where the
error occurred. Also, if several disks are used for the load, it will load again from head of
the disk in which the error occurred.
3
3
3
3
3
. If it is to be canceled without executing load, press the EXIT/NO key upon display of
"Retry?."
* You cannot abort a load operation on a SCSI device while it is in progress.
* To enter a title for the SCSI disk, go to “2-20. Drive Sel.?” menu in the Setup mode
and change the current drive to “SCSI,” then go to “2-4. Title Edit?” menu in the
Setup mode to enter the title.