Configuration and operating procedures

Configuring FortiBridge alerts

FortiBridge Version 3.0 Administration Guide
09-30000-0163-20061109

41

FortiBridge alert email

If you set the probe action on failure to alertmail, you can configure alert email
so that the FortiBridge unit sends an email message to up to three email
addresses if the FortiBridge unit detects a failure. The alert email informs the
recipient that a FortiGate unit has failed, includes the protocol for which the failure
was detected, and includes the serial number of the FortiGate unit that failed.

Only the first probe to detect a failure triggers the actions on failure. So, even if
multiple probes are configured, when a failure is detected, the FortiBridge unit
sends one alert email.

Figure 16: Sample FortiBridge alert email message

FortiBridge detect FortiGate failure

Time: Tue Feb 1 19:58:46 2005

failed protocol: http

failed FortiGate serial number: FGT8002803923050

To configure alert email

Configuring FortiBridge alert email is similar to configuring FortiGate alert email.

1

Log into the CLI.

2

Configure alert email. Enter:

config alertemail setting

set server mail.myorg.com

set username [email protected]

set password PassWORD

set mailto1 [email protected]

set mailto1 [email protected]

set mailto1 [email protected]

end

FortiBridge syslog

If you set the probe action on failure to syslog, you can configure FortiBridge
syslog so that the FortiBridge unit sends a syslog message to one syslog server if
the FortiBridge unit detects a failure. The message informs the recipient that a
FortiGate unit has failed, includes the protocol for which the failure was detected,
and includes the serial number of the FortiGate unit that failed.

Only the first probe to detect a failure triggers the actions on failure. So, even if
multiple probes are configured, when a failure is detected, the FortiBridge unit
sends one message.

Figure 17: Sample FortiBridge syslog messages

02-01-2005 18:22:50 Local7.Alert 172.20.120.13 date=2005-02-

01 time=15:28:22 device_id= log_id=0100020001 type=event

subtype=system pri=alert msg="FortiBridge detect FortiGate

failure: [failed time: Tue Feb 1 15:28:22 2005][failed

protocol: http] [failed FortiGate serial number:

FGT8002803923050]"