Connectors, Factory default configuration, Connectors factory default configuration – Fortinet Version 3.0 User Manual
Page 22
FortiBridge Version 3.0 Administration Guide
22
09-30000-0163-20061109
FortiBridge unit basic information
Setting up FortiBridge units
Connectors
Factory default configuration
Table 5: FortiBridge-1000 connectors
Connector Type
Speed
Protocol Description
INT 1
RJ-45
10/100/1000
Base-T
Ethernet
Copper gigabit ethernet connection to the internal
network.
EXT 1
RJ-45
10/100/1000
Base-T
Ethernet
Copper gigabit ethernet connection to the
external network.
INT 2
RJ-45
10/100/1000
Base-T
Ethernet
Copper gigabit ethernet connection to the
FortiGate unit internal interface.
EXT 2
RJ-45
10/100/1000
Base-T
Ethernet
Copper gigabit ethernet connection to the
FortiGate unit external interface.
CONSOLE
RJ-45
9600 bps
RS-232
serial
Optional connection to the management
computer.
Provides access to the command line interface
(CLI).
Table 6: FortiBridge-1000F connectors
Connector
Type
Speed
Protocol
Description
INT 1, INT 2,
EXT 1,
EXT 2, and
management
LC SFP
1000Base-SX
Ethernet
Multimode fiber optic connections
to gigabit optical networks. The
FortiBridge-1000F is shipped with
4 1000Base-SX Small Formfactor
Pluggable (SFP) transceivers that
you must insert into the INT 1, INT
2, EXT 1, and EXT 2 sockets on
the back panel. The management
connection is optional.
CONSOLE
RJ-45
9600 bps
RS-232
serial
Console connection to the
command line interface (CLI).
Table 7: FortiBridge-1000 and 1000F unit factory default network configuration
Administrator account
admin
Password
(none)
Management IP/Netmask
192.168.1.99/255.255.255.0
Management Access
Telnet, SSH and ping access to the INT 1
interface. No management access to the EXT 1
interface.
Routes
(none)
Primary DNS
65.39.139.53
Secondary DNS
65.39.139.63