beautypg.com

Technical specifications, Led indicators, Technical specifications led indicators – Fortinet Version 3.0 User Manual

Page 21

background image

Setting up FortiBridge units

FortiBridge unit basic information

FortiBridge Version 3.0 Administration Guide
09-30000-0163-20061109

21

Technical specifications

LED indicators

Table 2: FortiBridge-1000 and 1000F technical specifications

Dimensions

8.63 x 6.13 x 1.38 in. (21.9 x 15.6 x 3.5 cm)

Weight

1.5 lb. (0.68 kg)

Power
Requirements

DC input voltage: 5 V
DC input current: 5 A

Environmental
specifications

Operating temperature: 32 to 104°F (0 to 40°C)
Storage temperature: -13 to 158°F (-25 to 70°C)
Humidity: 5 to 95% non-condensing

Table 3: FortiBridge-1000 LED indicators

LED

State

Description

PWR

Green

The FortiBridge unit is powered on.

Off

The FortiBridge unit is powered off.

INT 1
INT 2
EXT 1
EXT 2

Green

The correct cable is in use and the connected equipment
has power.

Flashing Green

Network activity at this interface.

Off

No link established or the interface has been turned off.

INT 1
INT 2
EXT 1
EXT 2
(back)

Green

The correct cable is in use, and the connected equipment
has power.

Flashing amber

Network activity at this interface.

Off

No link established.

Table 4: FortiBridge-1000F LED indicators

LED

State

Description

PWR

Green

The FortiBridge unit is powered on.

Off

The FortiBridge unit is powered off.

INT 1,
INT 2,
EXT 1, and
EXT 2

Green

The correct optical fiber patch cable is connected to the
gigabit fiber interface.

Flashing

Network activity at the gigabit fiber interface.