2.6 Input Voltage and Fuses

The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions
and fuses as below.

Input voltage

Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.

Input

(TB-B101)

S603 S604 S605 Default

setting

100

V

L L L

110 V

H

L

L

115 V

H

H

L

220

V

H L H

230

V

H H H

Default

setting

Fuses

Change the fuse in F601 and F602 according to input voltage, referring to the table below.

Fuse

Input

(TB-B101)

F601 F602

Default

setting

100 V
110 V
115 V

20A 20A

220 V
230 V

10A 10A

Default
setting

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage
to the equipment or cause fire.

Marking the label

After setting toggle switches and changing the
fuses, mark the voltage which applies on the label
on the inside of the cover. In the example shown
right, 100 V is marked so 20A fuses must be used.

FUSE FUSE

F601 F602

INPUT

(TB-B101)

FUSE

F601 F602

100V
110V 20A 20A
115V
220V
230V

10A 10A