6 input voltage and fuses, Warning, Input voltage – Furuno FSV-30S User Manual
Page 40: Fuses, Marking the label
2-18
2.6 Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions
and fuses as below.
Input voltage
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.
Input
(TB-B101)
S603 S604 S605 Default
setting
100
V
L L L
110 V
H
L
L
115 V
H
H
L
220
V
H L H
230
V
H H H
Default
setting
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table below.
Fuse
Input
(TB-B101)
F601 F602
Default
setting
100 V
110 V
115 V
20A 20A
220 V
230 V
10A 10A
Default
setting
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Marking the label
After setting toggle switches and changing the
fuses, mark the voltage which applies on the label
on the inside of the cover. In the example shown
right, 100 V is marked so 20A fuses must be used.
FUSE FUSE
F601 F602
INPUT
(TB-B101)
FUSE
F601 F602
100V
110V 20A 20A
115V
220V
230V
10A 10A