1-13

1.6 Installing the Attachment Flange (option)

The attachment flange permits use of the tank for the CSH-20 series using the 1200 mm
stroke transducer.

Attachment flange Type: OP10-27, Code no: 000-067-050)

Name Type

Code

No.

Qty

Remarks

Attachment flange

10-077-5802

100-303-610

1

O-ring

CO 0318A (V585)

000-166-370-10

1

Hex. nut

M20 SUS304

000-863-116

48

Flat washer

M20 SUS304

000-864-136

24

Spring washer

M20 SUS304

000-864-270

24


Procedure

1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight amount of

grease.

2. Use 48 hex. nuts, flat washers and spring washers to fasten the attachment flange to

retraction tank.

3. Place the O-ring in position on the attachment flange.

To install the attachment flange and the hull unit, see paragraph 1.1.4.

Hex. Bolt

Flat Washer

O-ring

Spring Washer

Flat Washer

Hex. Nut

Attachment Flange

O-ring

Hex. Nut

Spring Washer

Flat Washer

Hull Unit Flange

Existing Tank

Attachment flange for 1200 mm stroke transducer, sectional view

This manual is related to the following products: