2.4 Transceiver Unit
2.4.1 Fabrication of connector 00-8016-038-313761HV (CN-B101)
400
45
40
Shield
Anticorrosive
Sheath
Armor
Vinyl Sheath
Core
Insulating Tape
After exposing cores,
wind shield around the armor.
Fabrication of cable for 00-8016-038-313761HV
Shorten the unused wires appropriately and treat their ends with vinyl tape to prevent short
circuit.
Guide Pin A
Guide Pin B
Guide Pin B
(Small)
Guide Pin A
(Large)
Position No.
Assembling 38P connector
Positioning guide pins
Use the tool shown below to position guide pins.
Guide Pin A (large)
Connector
Guide Pin
CN-B101
Guide Pin B (small)
1
1
Tool
This manual is related to the following products: