beautypg.com

Fortigate-5050 chassis, Fortigate-5005-dist interface names – Fortinet FortiGate-5000 User Manual

Page 71

background image

The FortiGate-5005-DIST security system FortiGate-5005-DIST

interface

names

FortiGate-5000 Series Introduction
01-30000-83466-20090108

71

FortiGate-5050 chassis

You can install one or two I/O boards in slot 1 and 2 of the FortiGate-5050 ATCA
chassis. You can also install up to three worker boards in slots 3 to 5 if two I/O
boards are being used, or four worker boards in slots 2 to 5 if one I/O board is
used. The FortiGate-5050 is a 5U chassis that contains two redundant DC power
connections that connect to -48 VDC Data Center DC power. The FortiGate-5050
chassis also includes a hot swappable cooling fan tray. For details about the
FortiGate-5050 chassis, see the

FortiGate-5050 Chassis Guide

.

Figure 33: FortiGate-5005-DIST components installed in a FortiGate-5050 chassis

FortiGate-5005-DIST interface names

The FortiGate-5005-DIST worker web-based manager and CLI use an internal
naming convention to name FortiGate-5005-DIST interfaces. The interface names
indicate the I/O board containing the interface and also include the I/O board front
panel interface name. The naming convention is:

port_
where:

is 1 for the interfaces of the primary I/O board installed in

chassis slot 1 and 2 for the interfaces of the secondary I/O board installed in
chassis slot 2. The interfaces for the secondary I/O board only appear in the
web-based manager and CLI when a secondary I/O board is installed.

is the name of the interface as shown on the

FortiController-5208 front panel.

Table 24 on page 72

shows the relationship between the names of the primary

and secondary board front panel interfaces and the interface names that appear
on the FortiGate-5005-DIST worker web-based manager and CLI.

1

2

2

3

4

5

SMC

1

SMC

POWER

5050SAP

SERIAL

1

SERIAL

2

ALARM

10/100
link/Act

ETH0

Service

RESET

ST

A

TUS

Hot Swap

link/Act

ETH0

ETH1

10/100

5000SM

10/100
link/Act

ETH0

Service

RESET

ST

A

TUS

Hot Swap

link/Act

ETH0

ETH1

10/100

5000SM

PAYLOAD OPERATION

STATUS

IPM

X 1

X 2

1/2

3/4

D15/D16

C15/C16

1

2

3

4

5

6

7

8

9

10

11

12

D

13

14

15

16

D

1

2

3

4

5

6

7

8

9

10

11

12

C

13

14

15

16

C

10/100/1000 MBPS ETHERNET ACTIVITY

DATA

CONTROL

1

2

3

4

MANAGEMENT

COM 1

COM 2

X 1

X 2

CONSOLE

ACT

ACT

LINK

LINK

F

A

BRIC

BASE

USB

USB

3

4

1

2

5

6

7

8

OOS

ACC

STATUS

IPM

CONSOLE

ACT

ACT

LINK

LINK

F

A

BRIC

BASE

USB

USB

3

4

1

2

5

6

7

8

OOS

ACC

STATUS

IPM

CONSOLE

ACT

ACT

LINK

LINK

F

A

BRIC

BASE

USB

USB

3

4

1

2

5

6

7

8

OOS

ACC

STATUS

IPM

CONSOLE

ACT

ACT

LINK

LINK

FA

B

R

IC

BASE

USB

USB

3

4

1

2

5

6

7

8

OOS

ACC

STATUS

IPM