beautypg.com

Leds – Fortinet FortiGate-5000 User Manual

Page 35

background image

FortiGate-5001A security system

Front panel LEDs and connectors

FortiGate-5000 Series Introduction
01-30000-83466-20090108

35

LEDs

Table 7

lists and describes the FortiGate-5001A LEDs.

Table 7: FortiGate-5001A LEDs

LED

State

Description

1, 2
(Left LED)

Green

The correct cable is connected to the interface and the

connected equipment has power.

Flashing

Green

Network activity at the interface.

Off

No link is established.

1, 2
(Right LED)

Green

Connection at 1 Gbps.

Amber

Connection at 100 Mbps.

Off

Connection at 10 Mbps.

Base CH0

Green

Base backplane interface 0 (base1) is connected at 1 Gbps.

Flashing

Green

Network activity at base backplane interface 0.

Base CH1

Green

Base backplane interface 1 (base2) is connected at 1 Gbps.

Flashing

Green

Network activity at base backplane interface 1.

Fabric CH0

Off

Fabric backplane interface 0 (fabric1) is connected at 10

Gbps.

Flashing

Green

Network activity at fabric backplane interface 0.

Fabric CH1

Off

Fabric backplane interface 1 (fabric2) is connected at 10

Gbps.

Flashing

Green

Network activity at fabric backplane interface 1.

ACC

Off or

Flashing

green

The ACC LED flashes green when the FortiGate-5001A

board accesses the FortiOS flash disk. The FortiOS flash

disk stores the current FortiOS firmware build and

configuration files. The system accesses the flash disk when

starting up, during a firmware upgrade, or when an

administrator is using the CLI or GUI to change the FortiOS

configuration. Under normal operating conditions this LED

flashes occasionally, but is mostly off.

OOS
(Out of
Service)

Off

Normal operation.

Green

A fault condition exists and the FortiGate-5001A blade is out

of service (OOS). This LED may also flash very briefly during

normal startup.

Power

Green

The FortiGate-5001A board is powered on.

Status

Off

The FortiGate-5001A board is powered on.

Flashing

Green

The FortiGate-5001A is starting up. If this LED is flashing at

any time other than system startup, a fault condition may

exist.

IPM

Blue

The FortiGate-5001A is ready to be hot-swapped (removed

from the chassis). If the IPM light is blue and no other LEDs

are lit the FortiGate-5001A board has lost power

Flashing

Blue

The FortiGate-5001A is changing from hot swap to running

mode or from running mode to hot swap. This happens when

the FortiGate-5001A board is starting up or shutting down.

Off

Normal operation. The FortiGate-5001A board is in contact

with the chassis backplane.