Fortigate-5140 chassis back panel – Fortinet FortiGate-5000 User Manual
Page 20
FortiGate-5140 chassis back panel
FortiGate-5140 chassis
FortiGate-5000 Series Introduction
20
01-30000-83466-20090108
Figure 3: FortiGate-5140 chassis front panel with FortiGate-5001SX, FortiGate-5001FA2, and
FortiSwitch-5003 boards installed
Also visible on the front of the FortiGate-5140:
• Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band
when working with the chassis.
• Front cable tray, used for managing and securing ethernet and other cables.
• Three hot swappable FortiGate-5140 cooling fan trays.
FortiGate-5140 chassis back panel
Figure 4
shows the back panel of the FortiGate-5140 chassis. The back panel includes
two hot-swappable redundant -48V/-60 VDC power entry modules (PEMs) labelled PEM A
and PEM B. Fortinet ships the FortiGate-5140 chassis with PEM A and PEM B installed.
The PEMs provide redundant DC power connections for the FortiGate-5140 chassis and
distribute DC power to the fan trays and to the FortiGate-5000 series boards installed in
the FortiGate-5140 chassis.
13
11
9
7
5
3
1
2
4
6
8
10
12
14
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
PWR
ST
A
IPM
CONSOLE
USB
1
2
3
4
5
6
7
8
ACC
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
MANAGEMENT
SYSTEM
E1
ZRE
LED MODE
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
E2
OK
CLK
INT
EXT
FLT
HOT SWAP
RESET
FLT
CONSOLE
E
T
H
O
R
S
2
3
2
Z
R
E
0
Z
R
E
1
Z
R
E
2
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
PWR
ACC
ST
A
IPM
CONSOLE
USB
3
4
1
2
5
6
7
8
Alarms
Rst
Serial 1
Serial 2
Min.
3
2
1
Crit.
Maj.
Link
Act
100
ETH 0
Stat.
Prim.
ShMC
Link
Act
100
ETH 0
Stat.
Sec.
ShMC
5140
FortiGate-5001FA2
boards
slots 4, 6, 8, 10,
12, and 14
FortiGate-5140
Shelf Manager
3 hot-swappable
cooling fan trays
(numbered 0, 1, and
2 behind panel)
FortiGate-5001SX
boards
slots 3, 5, 7, 9,
11, and 13
FortiSwitch-5003
boards
slots 1 and 2
Front cable
tray
ESD socket
Slot
numbers
Caution: Do not operate the FortiGate-5140 chassis with open slots on the front panel. For
optimum cooling performance and safety, the slots must contain a FortiGate-5000 series
board or an air baffle slot filler. As well the removable terminal block cover must be installed
over the power connectors on the back of the chassis.