beautypg.com

Fortigate-5140 chassis back panel – Fortinet FortiGate-5000 User Manual

Page 17

background image

FortiGate-5140-R chassis

FortiGate-5140 chassis back panel

FortiGate-5000 Series Introduction
01-30000-83466-20090108

17

http://docs.fortinet.com/

Feedback

Also visible on the front of the FortiGate-5140 chassis:
• Electrostatic discharge (ESD) socket, used for connecting an ESD wrist or ankle band

when working with the chassis.

• Front cable tray, used for managing and securing ethernet and other cables.
• Front accessible air filter.
• Three hot swappable FortiGate-5140 cooling fan trays.

FortiGate-5140 chassis back panel

Figure 2 on page 17

shows the back panel of the FortiGate-5140 chassis. The back panel

includes two hot-swappable redundant -48V/-60 VDC power entry modules (PEMs)
labelled A and B. Fortinet ships the FortiGate-5140 chassis with PEM A and B installed.
The PEMs provide redundant DC power connections for the FortiGate-5140 chassis and
distribute DC power to the chassis slots and to the fan trays.

Figure 2: FortiGate-5140 chassis back panel

If you require redundant power you should connect both PEMs to DC power. If redundant
power is not required, you should connect PEM A to DC power. Each PEM has four
-48V/-60 VDC connectors and 4 RTN connections. All eight of these connectors should be
connected to DC power.

Figure 2 on page 17

shows the terminal block cover removed

from PEM A and the wiring required to connect PEM A to DC power. While operating the
FortiGate-5140 both terminal block covers should be installed.

B

PEM

PEM

A

1

2

3

4

1

2

3

4

-48V/-60 VDC nom

RETURN

1

2

3

4

1

2

3

4

PEM

1

2

3

4

1

2

3

4

-48V/-60 VDC nom

RETURN

1

2

3

4

1

2

3

4

PEM

A

B

14

12

10

8

6

4

2

1

3

5

7

9

11

13

Power

Entry Module A

(terminal block

cover removed)

Power

Entry Module B

Chassis

ground

connector

(green)

-48V/-60 VDC

nom (black)

RTN

(red)

RTN

(red)

Back cable

tray

ESD

socket

TERMINAL BLOCK COVER

Remove terminal block cover and

decable before removing PEM.

TERMINAL BLOCK COVER

Remove terminal block cover and

decable before removing PEM.

-48V/-60 VDC

nom (black)

RTM

slot numbers

RTM

slot filler

panels