beautypg.com

Fortigate-5050 front panel – Fortinet FortiGate-5000 User Manual

Page 24

background image

FortiGate-5050 front panel

FortiGate-5050-R chassis

FortiGate-5000 Series Introduction

24

01-30000-83466-20090108

http://docs.fortinet.com/

Feedback

FortiGate-5050 front panel

Figure 5

shows the front of a FortiGate-5050 chassis. Two FortiSwitch-5003 boards are

installed in slots 1 and 2. Three FortiGate-5001SX boards are installed in slots 3, 4, and 5.
The FortiGate-5050 primary and secondary Shelf Managers and the Shelf Alarm Panel
(SAP) are also visible. The factory installed shelf alarm panel displays alarms, provides a
telco alarm interface, and also provides serial connections to the shelf managers. The
factory installed shelf managers provide power distribution, cooling, alarms, and shelf
status for the FortiGate-5050 chassis.

Figure 5: FortiGate-5050 front panel with FortiGate-5001SX and FortiSwitch-5003 boards

installed

Also visible on the front of the FortiGate-5050:
• The location of the hot swappable FortiGate-5050 cooling fan tray behind panel.
• Power LED.
• ESD socket, used for connecting an ESD wrist or ankle band when working with the

chassis.

1

2

2

3

4

5

SMC

1

SMC

POWER

5050SAP

SERIAL

1

SERIAL

2

ALARM

10/100
link/Act

ETH0

Service

RESET

ST

A

TUS

Hot Swap

link/Act

ETH0

ETH1

10/100

5000SM

10/100
link/Act

ETH0

Service

RESET

ST

A

TUS

Hot Swap

link/Act

ETH0

ETH1

10/100

5000SM

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

Hot-swappable

cooling fan tray

Power LED

FortiGate-5001SX

boards

slots 3, 4,

and 5

FortiSwitch-5003

boards

slots 1 and 2

Secondary

Shelf Manager

(SMC 2)

Primary

Shelf Manager

(SMC 1)

Shelf Alarm

Panel (SAP)

ESD socket

Caution: Do not operate the FortiGate-5050 chassis with open slots on the front panel. For
optimum cooling performance and safety, the slots must contain a FortiGate-5000 series
board or an air baffle slot filler. As well the removable power supply panel must be installed
over the power connectors on the back of the chassis.