beautypg.com

Reliability testing – NewTek TalkShow VS-100 User Manual

Page 96

background image

Page | 88

We know our products play vital roles in your productions. Durability and consistent,
robust performance are much more than just adjectives for your business and ours.

For this reason, all NewTek™ products undergo rigorous reliability testing to ensure they
meet our exacting test standards. In addition to our own exhaustive NewTek Hardware
Reliability Specifications, the following are applicable for TalkShow™:

Test Parameter

Evaluation Standard

Temperature

Mil-Std-810F Part 2, Sections 501 & 502

Ambient Operating

0°C and +40°C

Ambient Non-Operating

-10°C and +55°C

Humidity

Mil-STD 810, IEC 60068-2-38

Ambient Operating

20% to 90%

Ambient Non-Operating

20% to 95%

Vibration

ASTM D3580-95; Mil-STD 810

Sinusoidal

Exceeds ASTM D3580-95 Paragraph 10.4: 3 Hz to 500 Hz

Random

Mil-Std 810F Part 2.2.2, 60 minutes each axis,
Section 514.5 C-VII

Electrostatic Discharge

IEC 61000-4-2

Air Discharge

12K Volts

Contact

4K Volts