5 python module maintenance, 6 additional maintenance, 7 mb-10 decommissioning – Adept Python User Manual
Page 159
Python Module Maintenance
Adept Python Modules User’s Guide, Rev. E
159
15. The final step is to use the Linear Module Calibration Setup function in the
DC_Setup program to recalibrate the axis that had the new battery installed. See
for information on software configuration.
11.5 Python Module Maintenance
The ball screw, linear rail bearings, and ball bearings used in the Python linear modules
are lubricated for life. The ball screw nut and linear rail bearings are fully sealed to retain
the factory lubrication.
11.6 Additional Maintenance
Refer to the
Adept SmartController User’s Guide
for information on changing the lamp
for the Front Panel High Power Indicator.
11.7 MB-10 Decommissioning
Contact Adept Customer Service to determine when the MB-10 unit must be
decommissioned, or removed from service. If it is determined that the MB-10 is no longer
usable, then it must be disposed of according to all local and national regulations
regarding electronic components.
CAUTION:
Adding additional grease or oil to the ball
screw shaft on the linear rails could damage these seals
and reduce the life of the module.