Battery replacement procedure – Adept Python User Manual
Page 155
Replacing the MB-10 Internal Battery
Adept Python Modules User’s Guide, Rev. E
155
Battery Replacement Procedure
This procedure covers replacing the MB-10’s internal battery with a new replacement
battery.
1. Obtain a replacement battery. Adept part number: 04805-000 (see
Trim the leads to 2.5 ± 0.5 mm (0.10 ± 0.02 in.).
Figure 11-1. MB-10 Internal Battery and Retaining Clip
2. Turn off the 24 VDC power to the SmartController and turn off the AC power
switch on the PDU3.
3. At the PDU3, unplug the AC cable between the MB-10 and the PDU3.
4. Remove the cover from the MB-10 T-bracket and unplug all the cables from the
MB-10.
5. Remove the MB-10 amplifier from the T-bracket by loosening the four screws at
the corners of the MB-10. Carefully lift the MB-10 away from the bracket and set it
down on its heatsink fins, with the electronics facing upwards.
Table 11-2. MB-10 Internal Battery Replacement Periods
MB-10 24 V Power Status
Encoder Load
Recommended
Replacement Period
MB-10 powered more than
half time
MB-10 only
(No encoder OR ext. battery)
Not required
a
(10 years)
a
If an external battery is used for encoder backup, the MB-10 will function normally
even if the internal battery is exhausted. The only effect will be a loss of the time/date
stamp used for the internal error-logging function.
MB-10 not powered
MB-10 only
(No encoder OR ext. battery)
Not required
a
(10 years)
MB-10 powered more than
half time
MB-10 and encoder
(No external battery)
3 years
MB-10 not powered
MB-10 and encoder
(No external battery)
1.5 years
Battery
Retaining Clip