4 replacing the module encoder battery, Figure 11-2. mb-10 internal battery location, Figure 11-3. encoder battery – Adept Python User Manual
Page 156: Section 11.4
Chapter 11 - Maintenance
156
Adept Python Modules User’s Guide, Rev. E
6. Locate the M3 screw, washer, and sheet metal retaining clip which retain the
battery (see
). Remove the screw and washer.
Figure 11-2. MB-10 Internal Battery Location
7. Remove the clip by pulling straight up on the small tab with small pliers.
8. Remove the battery by pulling straight up with pliers or a similar tool.
9. Insert the replacement battery. Make certain the positive lead (+) is inserted into
the (+) marking on the circuit board. Be careful not to bend the leads on the
battery as you insert it.
10. Replace the clip and secure it with the screw and washer.
11. Reinstall the MB-10 amplifier onto the T-bracket assembly and reconnect all
cables. Turn on the AC and DC power to the system. See
12. The final step is to use the Calibration Set-up function in the DC_Setup program.
for information on software configuration.
11.4 Replacing the Module Encoder Battery
The encoder multi-turn data and module specification data stored by the encoder in the
module is protected by a backup battery. Each module is supplied from the factory with
the battery attached to the encoder harness and located inside the module’s motor cover.
See
.
Figure 11-3. Encoder Battery
Retaining clip
and battery
location
Screw