4 pdu3 connectors and indicators, Pdu3 – Adept Python User Manual
Page 124
Chapter 8 - Power Distribution Unit
124
Adept Python Modules User’s Guide, Rev. E
8.4
PDU3 Connectors and Indicators
1.
Status indicator LEDs:
24 V
- ON indicates 24 VDC power supply in the
PDU3 is working
AMP
- ON indicates 24 VDC to MB-10 is operating
AUX
- ON indicates 24 VDC to AUX is operating
CH1/2 -
E-Stop channel 1 or 2 voltage within range
ES1
- ON indicates E-Stop Relay 1 is on
ES2
- ON indicates E-Stop Relay 2 is on
Note
: both relays must be on to enable AC power
to MB-10 amps.
2. AMP DC RESET
button - for resetting the internal
circuit breaker on the 24 VDC supply to MB-10
amps
AUX DC RESET
button - for resetting the internal
circuit breaker on the 24 VDC supply to AUX
NOTE:
Do not push reset buttons while the system
is operating because it will cause 24 V power to
cycle and will require restarting the system.
3. XDCS
- connector for 24 VDC cable to MB-10 amps
This cable provides:
- 24 VDC to MB-10 amps
- 24 VDC to Aux/IO Blox
- Auto/Manual signals for Manual mode
operation
4. XSLV1/2
- (1) connection to host controller E-Stop
(2) connection for terminator plug
Note
: XSLV1 and 2 are interchangeable. The
terminator plug must be installed for the system to
operate.
5. AC PWR AMP
- connector for switched AC power
cable to MB-10 amps.
6. Circuit Breaker
- 6 Amp circuit breaker for
switched AC power going to MB-10 amps. Press
the button in to reset it if it has tripped.
7. AC PWR IN
- connector, fuses, and On/Off switch
for incoming AC power to PDU3.
NOTE:
200-240 VAC required for Python systems.
1
2
3
4
5
7
6
PWR
XDCS
PWR
AC
AMP
ES2
IN
1
AUX
ES1
XSLV1/
AC
CH1
CH2
24V
AUX DC RESET
XSLV2
PDU3
2
AMP DC RESET
C
I
C
U
I
T
B
R
A
K
E
R