beautypg.com

AltiGen MAXCS 7.5 Softswitch Deployment Guide User Manual

Page 23

background image

MAXCS 7.5 All-Software Solution Deployment Guide

Page 23 of 37


4. Edit or fill in parameters as needed. To edit a line, click

Edit and update the entry). Click OK.

SIP Server IP Address – The SIP Trunk service provider’s server IP address.

User Name – Assigned by the SIP Trunk service provider.

Password – Assigned by the SIP Trunk service provider.

Domain – The Domain Name of the SIP Trunk service provider, if required.

SIP Register Period – How frequently the AltiGen system needs to send SIP registration packets to

the service provider. This can detect if the service provider is up or not. Some service providers do

not accept SIP Register messages. In these cases, you can disable sending SIP Register

messages from MAXCS by setting the SIP Register Period to 0.

SIP Trunk Profile – Select the appropriate SIP trunk profile.

SIP Source Port – For SIP UDP, select the source port from 5060 or 10060. For TCP or TLS, you

cannot change ports. Using a port other than 5060 will prevent SIP-ALG firewall/router from

changing the SIP packets. Port 10060 is recommended, if the service provider supports it.

SIP Destination Port – A SIP Trunk can have different source port and destination port.

Automatic NAT Traversal – Leave this box unchecked.

Enable Channel – After all above parameters are entered correctly, check this box to activate the

channel. The AltiGen system will send authentication to the service provider to verify the setting.

5. To copy the information in one row to other rows, select the row and click

Copy To. Then select the

rows you want to copy the information to, using

CTRL+click and Shift+click to select several rows.

Click

OK.

If you need to delete a row, select it and click

Delete.