beautypg.com

AltiGen MAXCS 7.5 Softswitch Deployment Guide User Manual

Page 20

background image

Page 20 of 37

MAXCS 7.5 All-Software Solution Deployment Guide

When an IP phone registers to the system, a channel ID will be assigned to the IP extension. However, these

channels are only responsible for processing protocol and call control signals. They require a media path from

a VoIP board or from the IP phone to establish a voice steam so that both sides can hear.
Notes

Make sure you have enough VoIP resource boards.

The more signal channels in the system, the more system memory and CPU power is required.

Changing the number of signal channels requires that you restart the switching and gateway services.

SIP Trunking Channel requires a license to activate.

To configure the SIPSP board,

1. In MAXCS Administrator, open the Boards panel and double-click

SIPSP.

2. Click

Board Configuration. The SIP Signaling Channel Configuration panel opens. This panel shows

the number of configured channels and licensed channels.

3. Adjust the number of SIP extension channels and Tie-Trunk channels as needed.

By default, MAXCS is set to support 60 SIP extension channels. The maximum number possible

depends of the system CPU performance, call volume, and usage.
If a high performance machine is used as the Softswitch server, the number of channels can be more

than 1000.

4. After you adjust these values, you must restart the switching and gateway services for this change to

take effect. After the services restart, the new configuration will appear in the

Currently Configured