MAXCS 7.5 All-Software Solution Deployment Guide

13. After the files have been installed, click

Finish.

14. Click

Yes to restart the server.

Step 2: Run the HMCP Certification Tool

1. After the system restarts, click

Start > All Programs > AltiGen HMCP Certification Tool.

2. Stop all AltiGen switching services.
3. When the HMCP tool opens, in the Test Mode section, select

All In One. Set CPU Usage Threshold to

30%.

4. In the Codec Assessment section, enter the maximum number of codecs in those two fields (enter

2000 for both Max G.711 and Max Combo)

5. Click

Start Test in the Codec Assessment section.

6. Monitor the DPC Latency values. Instant latency should be less than 2000 us most of the time; Max

latency should be less than 6000 us.

7. Record the number of supported G.711 and Combo codecs in the test results. Then enter those

numbers in the Max G.711 Codec and Max Combo Codec fields (in the Codec Assessment section).

8. Under the System Load section, select both Disk IO access and Apply load to xx threads. Enter

1 for

the number of threads.

The tool will generate disk I/O access in the background and then measure DPC.

9. In the Test Mode section, set CPU Usage Threshold to

60%.

10. Click the

Start Test buttons in both the Codec Assessment section and the System Load section.

11. Monitor the DPC latency numbers. Instant latency should be less than 2000 us most of the time. Max

latency should be less than 6000 us.