Page 70

2. Does your pump use a C-face adapter?
• If Yes: Place one sling from the hoist through the frame adapter (108) or frame (228A) for the STi
and a second sling from the hoist through the C-face adapter.
• If No: Place a sling from the hoist through the frame adapter (108) or the frame (228A) for the
STi.
370F
370
108
418
351
340
100
3. Remove the hold-down bolts of the bearing frame foot.
4. Remove the casing bolts.
WARNING:
• Never use heat to disassemble the pump due to the risk of an explosion from trapped liquid.
5. Tighten the jackscrews evenly, using an alternating pattern, in order to remove the back pull-out
assembly.
You can use penetrating oil if the adapter to the casing joint is corroded.
6. Remove the back pull-out assembly from the casing (100).
7. Mark and remove the shims from under the frame foot and save them for reassembly.
8. Remove and discard the casing gasket.
You will insert a new casing gasket during reassembly.
9. Remove the jackscrews.
10. Clean all gasket surfaces.
Maintenance
68