Regrease the grease-lubricated bearings, Egrease the grease-lubricated bearings – Goulds Pumps CV 3196 i-FRAME - IOM User Manual
Page 64

Castrol
Hyspin R&O 220
Chevron
GST 220
Exxon
Teresstic 220
Mobil
DTE Oil BB
Mobil Gear 630
Shell
Marlina 220
Tellus 220
Sunoco
Sunvis 9220
Texaco
Regal R&O 220
Rando HD 220
Royal Purple
Synfilm GT 220
Synergy 220
Regrease the grease-lubricated bearings
NOTICE:
Make sure that the grease container, the greasing device, and the fittings are clean. Failure to do this can
result in impurities entering the bearing housing when you regrease the bearings.
193
113
1. Wipe dirt from the grease fittings.
2. Remove the two grease-relief plugs from the bottom of the frame.
3. Fill both of the grease cavities through the fittings with a recommended grease until the fresh grease
comes out of the relief holes.
4. Make sure that the frame seals are seated in the bearing housing.
If they are not, press them in place with the drains located at the bottom.
5. Reinstall the grease-relief plugs.
6. Wipe off any excess grease.
7. Recheck the alignment.
The bearing temperature usually rises after you regrease due to an excess supply of grease. Temperatures
return to normal in about two to four operating hours as the pump runs and purges the excess grease
from the bearings.
Maintenance
62
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual