Furuno – Furuno FS-5070 User Manual
Page 212
FURUNO
FS-1570/2570/5070
SP - 4
E5656S01A-M
080414
-60 dB: within ±550 Hz
2.4.8 Receiving System
Double-conversion superheterodyne
2.4.9 Radiation
within 2 nW
2.4.10 RX Error Rate
1 % or less at 1
μV input voltage
2.4.11 Spurious Response
31.6 mV non-modulated at 10
μV input voltage,
at error rate within 1%
2.4.12 Scanning Reception
max. 6 frequencies within 2 s (MF/HF)
2.4.13 Diagnosis
Transmit high frequency signal of DSC
3
NBDP FUNCTION (OPTION)
3.1 GENERAL
3.1.1 Communication mode ARQ, FEC, DIRC (FSK)
3.1.2 Protocol
ITU-R M625-3, M476-5, M490, M491-1, M492-6
ID code
4, 5, 9 column
Line cord
4B/3Y (Intl.)
Modulation
AFSK
Tone frequency
1615/1785Hz ± 0.5 Hz (mark/space)
Tracking range
±80 Hz
3.1.3 Applications
Auto-reception
Setting timer and frequency (max. 10 settings available)
Frequency scanning 10 group max., 20 station as each group
User-channels
100 channels max.
3.2 TERMINAL
UNIT IB-581 (FS-1570/2570)
3.2.1 Display
9.5” monochrome LCD, 680 x 480 dots
3.2.2 CPU
ALI M6117 (33 MHz)
3.2.3 Memory
Flash ROM 2 MB, DRAM 2 MB
3.2.4 FD Drive
1.44MB 3.5”
3.2.5 Keyboard
82 keys, IBM PS/2
3.3 TERMINAL UNIT IB-583
3.3.1 Display
10.4” color TFT LCD, 640 x 480 dots
3.3.2 CPU
HD6417615 (15.5 MHz)
3.3.3 Memory
Flash ROM: 1 MB, S-RAM: 256 KB
3.3.4 FD drive
1.44MB 3.5”
3.3.5 Keyboard
82 keys, IBM PS/2
3.3.6 Other functions
Text editor, FD control, Printer, Remote control for Transceiver,
Diagnosis