11. MAINTENANCE & TROUBLESHOOTING

11-8

TEST ACKNOWLEDGEMENT

SENDER ID :

001234567

PRIORITY: SAFETY

*

Received message

*

GO TO VIEW

MAR-23-2006-23:59

3M10S

No response! Try calling again?

Re-send call: Push the ENTER knob and then press the CALL key.
Cancel call: Press the CANCEL key to return to the previous screen.

11.7 NBDP Terminal Unit Maintenance

Regular maintenance is important for good performance. A regular maintenance program
should be established and should at least include the items mentioned below.

11.7.1 Cleaning

the

equipment

Wipe off accumulated dust from the terminal unit with a soft cloth. Wipe the LCD carefully to
prevent scratching, using tissue paper and an LCD cleaner. To remove dirt or salt deposits,
use an LCD cleaner, wiping slowly with tissue paper so as to dissolve the dirt or salt.
Change paper frequently so the salt or dirt will not scratch the surface of LCD. Do not use
solvents such as thinner, acetone or benzene for cleaning; they can remove paint and
marks or deform the equipment.

11.7.2 Connectors and earth connection

Periodically check the connectors for proper seating and the earth connection for rust.
Remove rust to maintain a good ground system.

11.7.3 Floppy disk drive

Foreign material on the floppy disk drive head can scratch the magnetic material in the
floppy, resulting in loss of data. Clean the floppy disk drive head regularly with a floppy disk
drive cleaning disk to prevent erasure of information stored on disks.

11.7.4 Diagnostics

General diagnostics
1. Press the function key F6 to display the System menu.