beautypg.com

Furuno RC-1500-1T User Manual

Page 78

background image

4-2

3. Press the [ENT] key to display the PRIORITY menu.

***

Send message

***

CALL TYPE:

ALL SHIPS

COM. TYPE

: TELEPHONE

DSC FREQ : 2187.5 KHZ

GO TO ALL VIEW

PRIORITY

SAFETY

URGENCY

4. Select SAFETY or URGENCY as appropriate and press the [ENT] key.

5. Press the [ENT] key to open the COM. TYPE menu.

***

Send message

***

CALL TYPE :

ALL SHIPS

PRIORITY :

SAFETY

COM TYPE

DSC FREQ

: 2187.5 KHZ

GO TO ALL VIEW

COM. TYPE

NBDP-FEC

TELEPHONE

6. Select communication type desired and press the [ENT] key.

7. Press the [ENT] key to open the DSC FREQ menu.

***

Send message

***

GO TO ALL VIEW

DSC FREQ

CALL TYPE

: ALL SHIPS

PRIORITY

: SAFETY

COM TYPE

: TELEPHONE

2187.5KHZ

4207.5
6312.0
8414.5
12577.0
16804.5
MANUAL

2187.5

MANUAL: For manual selection of frequency at
radiotelephone when there is "remote control error."

8. Select frequency and press the [ENT] key.

9. Press the [CALL] key to send the call (transmission time: about 7 sec.). The display shows

"All ships call in progress!" while the call is being sent.

SAFETY

TELEPHONE

2182.0 KHZ

All ships
call in progress!

DSC FREQ :

2187.5 KHZ

TIME TO GO:

5S

10. The DSC standby screen automatically appears after the call is sent (timer counts down to

zero). The equipment is set up for telephone (or NBDP) and safety or urgency priority, using
DSC safety/urgency pair frequencies.