SP - 11
SPECIFICATIONS OF THE AC/DC CHANGE-OVER UNIT
(RADIO SWITCH BOX)
1. BATTERY CHARGER (BC-6158)
(1) Applicable Battery
200AH Normal ship battery
(2) Power Source
100/110/115/220/230 VAC, 1 phase, 60 Hz or 24 VDC
(3) Output for Battery
24 VDC, 30 A nominal
(4) Charge/discharge Meter
built in the radio console panel
(5) Control Panel
built in the radio console
2. RECTIFIER (PR-850AR)
(1) Power Source
100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC
(2) Input Current
15 A or less (AC input), 30 A or less (DC input)
(3) Rush Current
80 A or less
(4) Output Voltage
DC24 V ±10%, 30 A
(5) Peak Output Current
60 A (60 A output with 1 min AC or 40 A within 1 min DC)
(6) Ripple Voltage
100 mVp-p or less
(7) Insulation Resistance
500 VDC, 50 M
Ω
or more between AC input and chassis
3. RECTIFIER (PR-300)
(1) Power Source
100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC
(2) Input Current
2 A or less (AC input), 3.1 A or less (DC input)
(8) Rush Current
80 A or less
(3) Output Voltage
24 VDC ±10%, 7.5 A
(4) Peak Output Current
20 A (10 A output within 2H or 20 A within 15 min)
(5) Ripple Voltage
100 mVp-p or less
(9) Insulation Resistance
500 VDC, 50 M
Ω
or more between AC input and chassis