Henny Penny PRESSURE FRYERS 600 User Manual
Page 61

Model 500/600
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-15”
Drain switch
Close drain, using the drain valve handle; if display still
“DRAN IS failure
shows “E-15”, have the drain microswitch checked
OPEN”
“E-20C”
Ignition module(s)
Turn switch to OFF, then back to COOK to try the ignition
(SSI gas fryers failure
process again, and if “E-20C” persists, have ignition modules
only)
checked
“E-20D”
No ignition
Turn switch to OFF, then back to COOK to try the ignition
(SSI gas fryers
process again, and if “E-20D” persists, have gas valve and gas
only)
flow checked
“E-41”
Programming
Turn switch to OFF, then back to COOK; if display shows any
“E-46”
failure
of the error codes, try to reinitialize the control (Section 2-3);
if error code persists, have the control board replaced
“E-70A”
Missing or broken
Have jumper wire between pins 1 and 2 checked
wire in pins 1 and
2 of P11 connector,
or faulty connector
Faulty I/O board
Have I/O board checked and replaced, if necessary
“TEMP TOO”
Possible water
Make sure oil is in frypot and at the proper level
LOW FOR
in frypot
PRESSURE”
3-2. ERROR CODE TABLE
(Continued)
108
5-3