Henny Penny PRESSURE FRYERS 600 User Manual
Page 39
Model 500/600
1207
3-15
3-6. REGULAR MAINTENANCE
SCHEDULE
Procedure
Frequency
Filtering of shortening
Every 3 to 6 frying cycles
Filter pump problem prevention
As required
Changing of shortening
As required
Changing the filter envelope
As required
Cleaning the frypot
Before changing the shortening
Cleaning the deadweight valve
Daily
Night closing procedures
Daily
Check optional rinse hose
Weekly
for deterioration
Reversing the lid gasket
Quarterly
Lid lubrication
Quarterly
Limit stop adjustment
Quarterly
Check tightness of spreader bars
Quarterly
Clean safety relief valve
Annually
The filter pump motor is equipped with a manual reset button,
located on the rear of the motor, in case the motor overheats. Wait
about 5 minutes before attempting to reset this protective device to
allow motor to cool. The filter motor is on the rear of the fryer. It
takes some effort to push the reset, and a screwdriver can be used to
help reset the button.
Electric fryers with serial numbers of HB013JB & below, and gas
fryers with serial numbers of GA085JB & below, can push the reset
button, by removing the access panel on the left side panel of the unit.
To prevent burns caused by splashing shortening, turn
the unit’s main power switch to the OFF position before
resetting the filter pump motor’s manual reset protection
device.
3-7. FILTER PUMP
MOTOR
PROTECTOR-
MANUAL RESET
As in all food service equipment, the Henny Penny pressure fryer does
require care and proper maintenance. The table below provides a
summary of scheduled maintenance.