Henny Penny PRESSURE FRYERS 600 User Manual
Page 60
Model 500/600
5-2. ERROR CODES
This section provides error codes and their
information in the form of an easy-to-read table.
If a problem occurs during the first operation of a
new fryer, recheck the Installation Section .
5-3. ERROR CODE TABLE
In the event of a control system failure, the digital
display shows an error message coded as follows:
“E-4”, “E-5”, “E-6”, “E-10”, “E-15”,
“E-20-A, B, D”, “E-41”, “E-46”, & “E-70.
An alarm sounds when an error code is displayed,
and to silence this alarm, press any button.
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-4”
Control board
Turn switch to OFF position, then turn switch back to ON;
“CPU TOO
overheating
if display shows “E-4”, the control board is getting too hot;
HOT”
check the louvers on each side of the unit for obstructions;
check cooling fan, if present
“E-5” “OIL
Shortening
Turn switch to OFF position, then turn switch back to ON; if
TOO HOT”
overheating
display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6A”
Temperature
Turn switch to OFF position; then turn switch back to ON; if
“OIL PROB
probe open
display shows “E-6”, have the temperature probe checked
OPEN”
“E-6B”
Temperature
Turn switch to OFF position, then turn switch back to ON; if
“OIL PROB
probe shorted
display shows “E-6”, have the temperature probe checked
SHRT”
“E-10”
High limit
Reset the high limit by manually pushing up on the reset
“HIGH
button; if high limit does not reset, high limit must be
LMT TRIP”
replaced
5-2