beautypg.com

Henny Penny PRESSURE FRYERS 600 User Manual

Page 12

background image

Model 500/600

2-2. UNPACKING

INSTRUCTIONS (Continued)

5. Remove the four leg bolts from the wooden shipping base.

Remove and discard the wooden base.

6. Thread the shipping bolts back into the legs to provide leveling

adjustment feet. If ordered, install casters into the legs, with the
locking casters in front.

7. Place fryer in an upright position.

8. Prepare the deadweight assembly for operation:

The metal shipping support is placed within the deadweight
assembly housing to protect the deadweight orifice and
deadweight during shipment. This support must be removed
prior to installation and start-up.

a.

Unscrew the deadweight cap.

b.

Remove the round deadweight.

c.

Remove and discard the shipping support.

d.

Clean the deadweight orifice with a dry cloth.

e.

Replace the deadweight and secure the deadweight cap.

9. Open lid and remove packing and racks from inside of frypot.

10. Remove the protective paper from the fryer cabinet.

It is necessary to clean exterior surface with a damp cloth.

Step 8

2-2

1207

Cap