beautypg.com

Technical data for ce marked products – Henny Penny PRESSURE FRYERS 600 User Manual

Page 6

background image

Model 500/600

Technical Data for CE Marked Products

Nominal Heat Input:

Natural (I

2H

) = 21.1 KW (72,000 Btu/h)

(Net)

Natural (I

2E

) = 21.1 KW (72,000 Btu/h)

Natural (I

2E+

) = 21.1 KW (72,000 Btu/h)

Natural (I

2L

) = 21.1 KW (72,000 Btu/h)

Liquid Propane (I

3P

) = 21.1 KW (72,000 Btu/h)

Nominal Heat Input:

Natural (I

2H

) = 23.4 KW (80,000 Btu/h)

(Gross)

Natural (I

2E

) = 23.4 KW (80,000 Btu/h)

Natural (I

2E+

) = 23.4 KW (80,000 Btu/h)

Natural (I

2L

) = 23.4 KW (80,000 Btu/h)

Liquid Propane (I

3P

) = 22.9 KW (78,000 Btu/h)

Supply Pressure:

Natural (I

2H

) = 20 mbar

Natural (I

2E

) = 20 mbar

Natural (I

2E+

) = 20/25 mbar

Natural (I

2L

) = 25 mbar

Liquid Propane (I

3P

) = 30 mbar

Liquid Propane (I

3P

) = 37 mbar

Liquid Propane (I

3P

) = 50 mbar

Test Point Pressure:

Natural (I

2H

) = 8.7 mbar

Natural (I

2E

) = 8.7 mbar

Natural (I

2E+

) = 8.7/10 mbar

Natural (I

2L

) = 10 mbar

Liquid Propane (I

3P

) = 25 mbar

Injector Size:

Natural (I

2H

) = 1.04 mm

Natural (I

2E

) = 1.04 mm

Natural (I

2E+

) = 1.04 mm

Natural (I

2L

) = 1.04 mm

Liquid Propane (I

3P

) = 0.66 mm

Restrictor Size:

Natural (I

2E+

) = 4.1 mm

This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force
and only used in a suitably ventilated location. Read the instructions fully before installing or using the appliance.