Model 500/600
3-6
1207
3-2. OPERATING COMPONENTS
(Continued)
Fig.
Item
Description
Function
No.
No.
4
22
Circuit Breakers
A protective device which breaks the circuit when the current
(Electric Models Only)
exceeds the rated value
5
23
Contactors
Relays that route power to the heating elements; one relay is in
(Electric Models Only)
series with the high limit, the other one is in series with the controls
5
24
Transformer
Reduces the voltage down to accommodatethose components with
low voltage
8
25
High Temperature A control that senses the temperature of the shortening; if the
Limit
temperature of the shortening exceeds the safe operating limit, this
control opens and shuts off the heat to the frypot; when the
temperature of the shortening drops to a safe operation limit, the
control must be manually reset by pressing the red reset button,
located under the control panel, behind the door
9
26
Circuit Breaker
Opens the electrical circuit, and removes power to elements
(Single Phase
Electrics Only)
Gas
Electric