When the icemaker is not used for two or three days, it is sufficient to only move
the Control Switch to the “OFF” position, unless the icemaker will be at sub-freezing
temperatures.

[a] Remove the water from the potable water supply line:

1) Remove the Air Filter if it has not already been removed.

2) Move the Control Switch on the Control Box to the “OFF” position.

3) Wait 3 minutes.

4) Close the potable water supply line Shut-off Valve and open the potable water

supply line Drain Valve. See Fig. 32.

5) Allow the line to drain by gravity.

6) Attach compressed air or carbon dioxide supply to the potable water supply line

Drain Valve.

7) Move the Control Switch to the “ICE” position.

8) Quickly blow the potable water supply line out using compressed air or carbon

dioxide.

[b] Drain the potable Water Tank:

1) Turn off the power supply at the breaker box.

2) Move the Control Switch on the Control Box to the “OFF” position.

3) Open the Door. Disconnect the Silicone Hose to drain the water. See Fig. 23.

4) Reconnect the Silicone Hose back in its correct position after all of the water has

drained.

5) Remove all ice from the Storage Bin and clean the Storage Bin.

6) Close the Door.

7) Place the Air Filter in its correct position.

8) Close the potable water supply line Drain Valve.