8. PUMP MOTOR

1) Unplug the icemaker or disconnect the power source.

2) Remove the Top Panel and unscrew the Rear Panel.

3) Disconnect the Connector of the Pump Motor lead.

4) Remove the Water Tank (see “16. WATER TANK”).

5) Remove the ties connecting the Pump Motor discharge outlet and pull off the

Silicone Hose. Do not lose the Orifice coming off with the Hose.

Fig. 8

6) Remove the screw securing the Pump Motor. Shift the Case to the center to release

it from the Stopper, and lift off the Pump Motor.

Tie

Orifice

Silicone Hose

7) Install the new motor in the reverse order of the removal procedure.

8) Plug in the icemaker or connect the power source, and check for leaks.

9) Refit the panels in their correct positions.

Fig. 9

Stopper

Screw

Slide to center