43

WARNING

Always protect the valve body by using a damp cloth to prevent the valve
from overheating. Do not braze with the valve body exceeding 274°F.

8) Install the new Drier (see “4. DRIER”).

9) Check for leaks using nitrogen gas (140 PSIG) and soap bubbles.

10) Evacuate the system and charge it with refrigerant (see “1. [c] EVACUATION AND

RECHARGE”).

11) Attach the Solenoid Coil to the valve body, and secure it with the screw.

12) Connect the lead wires.

13) Refit the panels in their correct positions.

14) Plug in the icemaker or connect the power source.