beautypg.com

Hoshizaki KM-151BAH User Manual

Page 47

background image

42

5. HOT GAS VALVE

CAUTION

To ensure optimum performance, use a copper tube of the same diameter
and length for replacement of the hot gas circuit.

IMPORTANT

Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repair or replacement
has been made.

1) Unplug the icemaker or disconnect the power source.

2) Remove the Rear Cover.

3) Recover the refrigerant and store it in a proper container, if required by an applicable

law (see “1. [b] REFRIGERANT RECOVERY”).

4) Disconnect the Hot Gas Valve leads.

5) Remove the screw and the Solenoid Coil.

6) Remove the valve and Drier using brazing equipment.

7) Braze the new Hot Gas Valve with nitrogen gas flowing at a pressure of 3 - 4 PSIG.

Fig. 5

Hot Gas Valve

Air-Cooled Condenser