beautypg.com

Hoshizaki KM-151BAH User Manual

Page 37

background image

32

PROBLEM POSSIBLE

CAUSE

REMEDY

1. Connector

disconnected.

1. Reconnect.

2. Leads opened or

defective switch.

2. Check and replace.

a) Float Switch

3. Float does not move

freely.

3. Clean or replace.

[2] Water

continues to
be supplied,
and the
icemaker will
not start.

b) Control Board

1. Defective.

1. Replace.

1. WASH position.

1. Move to ICE position.

a) Control Switch

2. Bad contacts.

2. Check and replace.

1. Dirty Air Filter or

Condenser.

1. Clean.

2. Ambient temperature

too warm.

2. Reduce ambient

temperature.

3. Refrigerant

overcharged.

3. Recharge.

4. Fan not operating.

4. See chart 2 - [6].

b) High Pressure

Control (KM-151
only)

5. Refrigerant line or

components plugged.

5. Clean and replace Drier.

1. Bad contacts.

1. Check for continuity and

replace.

2. Voltage too low.

2. Increase voltage.

c) Overload

Protector

3. Refrigerant overcharged

or undercharged.

3. Recharge.

1. Bad contacts.

1. Check and replace.

d) Starter

2. Coil winding opened.

2. Replace.

e) Start Capacitor

1. Defective.

1. Replace.

1. Bad contacts.

1. Check for continuity and

replace.

f) Power Relay

2. Coil winding opened.

2. Replace.

1. Wiring to Compressor.

1. Check for loose

connection or open, and
replace.

2. Defective.

2. Replace.

g) Compressor

3. Protector tripped.

3. Reduce temperature and

verify cause.

h) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.

[3] Compressor

will not start or
operates
intermittently.

i) Condenser, Air

Filter

1. Clogged with dirt and

dust.

1. Clean and unclog.

a) Inlet Water Valve

1. Diaphragm does not

close.

1. Check for water leaks

with icemaker off.
Replace if necessary.

[4] Water

continues to
be supplied in
freeze cycle.

b) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.