6. OTHER

PROBLEM POSSIBLE

CAUSE

REMEDY

1. Completely

disconnected and
dropped inside bin.

1. Place in position.

2. Detector broken.

2. Replace.

3. Detector out of position.

3. Place in position.

4. Defective reed switch.

4. Check for continuity and

replace.

5. Reed switch out of

position.

5. Place in position.

a) Bin Control Switch

6. Magnet disconnected

from Detector.

6. Place in position.

[1] Icemaker will

not stop when
bin is filled with
ice.

b) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.

a) Pump Motor

1. Bearings worn out.

1. Replace.

1. Bearings worn out.

1. Replace.

2. Fan blade deformed.

2. Replace fan blade.

b) Fan Motor

3. Fan blade does not

move freely.

3. Replace.

1. Bearings worn out, or

cylinder valve broken.

1. Replace.

c) Compressor

2. Mounting pad out of

position or loose
hold-down bolt.

2. Reinstall.

[2] Abnormal

noise

d) Refrigerant Lines

1. Rub or touch lines or

other surfaces.

1. Reposition.

[3] Ice in Storage

Bin often
melts.

a) Bin Drain

1. Plugged.

1. Clean.