31

2. NO ICE PRODUCTION

PROBLEM POSSIBLE

CAUSE

REMEDY

1. OFF position.

1. Move to ON position.

2. Loose connections.

2. Tighten.

3. Bad contacts.

3. Check for continuity and

replace.

4. Voltage too high.

4. Check and get

recommended voltage.

a) Power Supply

5. Unplugged.

5. Plug in.

b) Fuse (inside fused

disconnect, if any)

1. Blown out.

1. Check for short circuit and

replace.

1. OFF or WASH position.

1. Move to ICE position.

c) Control Switch

2. Bad contacts.

2. Check for continuity and

replace.

1. Tripped with bin filled

with ice.

1. Remove ice.

d) Bin Control Switch

2. Defective reed switch.

2. Check for continuity and

replace.

e) High Pressure

Control (KM-151
only)

1. Bad contacts.

1. Check for continuity and

replace.

f) Transformer

1. Thermal fuse blown out

or coil winding opened.

1. Replace.

g) Wiring to Control

Board

1. Loose connections or

open.

1. Check for continuity and

replace.

h) Thermistor

1. Leads shorted or open

and High Temperature
Safety operates. If
open, unit will start but
have long harvest cycle.

1. See “II. 4. HARVEST

CONTROL -
THERMISTOR”.

i) Hot Gas Solenoid

Valve

1. Continues to open in

freeze cycle and High
Temperature Safety
operates.

1. Check for power off in

freeze cycle and replace.

j) Water Supply Line

1. Water supply off and

water supply cycle does
not finish.

1. Check and get

recommended pressure.
Check for water supply.

1. Mesh filter or orifice

gets clogged and water
supply cycle does not
finish.

1. Clean. Replace if

necessary.

2. Coil winding opened.

2. Replace.

k) Inlet Water Valve

3. Wiring to Water Valve.

3. Check for loose

connection or open, and
replace.

[1] The icemaker

will not start.

l) Control Board

1. Defective.

1. See “II. 3. [d] CONTROL

BOARD CHECK
PROCEDURE”.