Setting the autoloader, To operate in sequential – Exabyte MAGNUM 1X7 LTO User Manual
Page 54
38
P
RODUCT
M
ANUAL
1012581
C
HAPTER
3—C
ONFIGURING
THE
A
UTOLOADER
d.
d.
d.
d.
When you have entered the desired Subnet mask, press
. The gateway
address selection screen appears:
e.
e.
e.
e.
Use
or
to move through the segments of the address (as indicated
by the underscore). Use
and
to increase or decrease the value of
an address segment. Press and hold
and
to move rapidly through
the available values.
f.f.f.f.
When you have entered the desired Gateway address, press
. A
confirmation message appears:
g.
g.
g.
g.
Press
to enact the change (or
if you don’t want to make the
changes).
9.
9.
9.
9.
Press
(as needed) to return to the Home screen.
Note:
If you set DHCP on, you can view the current server-assigned IP address
for the autoloader through the Status menu (see
).
S
ETTING
THE
A
UTOLOADER
TO
O
PERATE
IN
S
EQUENTIAL
M
ODE
The operating mode determines how the autoloader processes cartridges.
There are two operating modes:
Random (the default)–The autoloader processes cartridges according to
commands issued from an application.
Sequential–The autoloader processes cartridges sequentially without
direction from an application.
To customize how sequential mode works, you can set the Restart and Loop
options:
Restart option. The Restart option determines what the autoloader does
after it is reset or power cycled. The autoloader can either restart at the
beginning of the cartridge sequence (Restart option ON) or resume
where it left off when the interruption occurred (Restart option OFF).
S e t
G a t e w a y
A d r .
0 0 0 . 0 0 0 . 0 0 0 . 0 0 0
S e t
D H C P
o f f
a n d
n e w
I P
A d d r
N o w ?
!
! !
!
Important
If you are using a backup application which is capable of
controlling the autoloader, do not configure the library to
operate in Sequential mode.