Table c-1 – Exabyte MAGNUM 1X7 LTO User Manual
Page 150
134
P
RODUCT
M
ANUAL
1012581
A
PPENDIX
C—E
RROR
M
ESSAGES
Table C-1 Autoloader error messages
Error Message
Description
Corrective Action
Bootblock
An error occurred during a firmware
upload to the autoloader.
1.
Verify that you loaded the correct code.
Do not load firmware from one model
of autoloader or autoloader into
another.
2.
Reset the autoloader (see
) and
reload the firmware.
3.
If the error persists, contact Exabyte
Technical Support (see
) or your
service provider.
Cartridg.Invalid
An attempt was made to load an
incompatible cartridge into the tape
drive or a spent cleaning cartridge
and the cartridge was ejected.
Remove the cartridge from the
autoloader and replace it with one that is
compatible with the tape drive.
If you were attempting to import a
cleaning cartridge, insert a cartridge with
cleaning cycles remaining on it.
Command Failed
Check Ship Lock
The cartridge loader could not move
because it may be locked in place by
the shipping key.
Remove the shipping key (see
).
Command Failed
Drive is Full
A command was issued from the
operator panel to load a cartridge
into the tape drive when the drive
already contained a cartridge.
Wait until the current cartridge is unloaded
by the application, or use the operator
panel to unload it from the tape drive (see
).
Command Rejected
Carousel Full
A command was issued from the
operator panel to insert a cartridge
into the autoloader when all of the
cartridge cells were already full.
Export a cartridge from the autoloader to
make room for a new cartridge (see
).
Command Rejected
Empty Carousel
A command was issued from the
operator panel to either load a
cartridge into the tape drive or
remove a cartridge from the
autoloader when there were no
cartridges in the cartridge carousel.
Wait until the cartridge is ejected from the
tape drive, or use the operator panel to
import cartridges into the autoloader (see
).
Configuration
Locked by Host
The application is currently
controlling the autoloader (a SCSI
command is active) or the Remote
)
is controlling the autoloader.
Wait for the command from the application
to complete.
Device Not Ready
The autoloader is not ready to
perform the requested operation
because it is performing diagnostics
or its power-on self-test (POST).
Wait until the autoloader has finished, then
retry the operation.