You must log into the master file server to rename the print server.
Default name: the Ethernet Card’s S-digit serial number.

When you rename the print server, EPCONFIG rewrites the new
name EEPROM on the interface board, and re-assigns the name in

the Novell bindery on the master file server. If the Ethernet Card is

configured to serve queues on other file servers, use PCONSOLE
to assign the same new name on all the other file servers.

Note:

For a more convenient method

of

renaming, use EPSETUP which

renames the print server on all file servers the Ethernet Card services.

Example: EPCONFIG 06405980 N=E NN=lpsales1

Set Pass word

EPCONFIG

serial-number N=E NP=new_password

You must log into the master file server to change the password.

For

NP=new_password, you can enter up to 127 characters. (The

number of characters you can enter is limited by DOS.) Enter

“NP=” to delete a previously defined password. “No password” is

the default.

After changing the password on the master file server, you must

assign the same print server password on all file servers that the

Ethernet Card services. You can use PCONSOLE, if desired.

For a more convenient method of changing password, use
EPSETUP. EPSETUP changes the print server’s password on all file
servers that the Ethernet Card services.

Example: EPCONFIG 06405980 N=e NP=orange