Test Without Motor Function

The test without a motor is used to check the operation of the host controller and peripheral devices by simu-

lating the operation of the servomotor in the SERVOPACK, i.e., without actually operating a servomotor. This

function enables you to check wiring, verify the system while debugging, and verify parameters, thus shorten-
ing the time required for setup work and preventing damage to the machine that may result from possible mal-

functions. The operation of the motor can be checked during performing this function regardless of whether

the motor is actually connected or not.

Use Pn00C.0 to enable or disable the test without a motor.

4.5.1

Motor Information

The motor information that is used for a test without a motor is given below.

(1) Motor Connected

If a motor is connected, the information from the connected motor is used for the motor and encoder informa-

tion. The set values of Pn00C.1 and Pn00C.2 are not used.

(2) Motor Not Connected

The virtual motor information that is stored in the SERVOPACK is used. The set values of Pn00C.1 and
Pn00C.2 are used for the encoder information.

Encoder Resolution

The encoder information for the motor is set in Pn00C.1.

Encoder Type

The encoder information for the motor is set in Pn00C.2.

Parameter

Meaning

When

Enabled

Classification

Pn00C

n.

0

[Factory setting]

Disables the test without a motor.

After restart

Setup

n.

1

Enables the test without a motor.

Reference

Reference

Response

Response

Host controller

SERVOPACK

Simulates the operation
without motor.

M-II

Parameter

Meaning

When

Enabled

Classification

Pn00C

n.

0

[Factory setting]

Sets 13 bits as encoder resolution for the test without a
motor.

After restart

Setup

n.

1

Sets 20 bits as encoder resolution for the test without a
motor.

Parameter

Meaning

When

Enabled

Classification

Pn00C

n.

0

[Factory setting]

Sets an incremental encoder as encoder type for the test
without a motor.

After restart

Setup

n.

1

Sets an absolute encoder as encoder type for the test
without a motor.