beautypg.com

Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-II User Manual

Page 301

background image

9 Appendix

9.1.2 Parameters

9-22

Pn810

2

Exponential Function Accel-
eration/Deceleration Bias

0 to 65535

100

reference

unit/s

0

Immedi-

ately

*4

Setup

*1

Pn811

2

Exponential Function Accel-

eration/Deceleration Time
Constant

0 to 5100

0.1 ms

0

Immedi-

ately

*4

Setup

*1

Pn812

2

Movement Average Time

0 to 5100

0.1 ms

0

Immedi-

ately

*4

Setup

*1

Pn814

4

Final Travel Distance for
External Positioning

-1073741823

to

1073741823

1

reference

unit

100

Immediately

Setup

*1

Pn816

2

Homing Mode Setting

0000

Immediately

Setup

*1

Pn817

*5

2

Homing Approach Speed 1

0 to 65535

100

reference

unit/s

50

Immedi-

ately

*3

Setup

*1

Pn818

*6

2

Homing Approach Speed 2

0 to 65535

100

reference

unit/s

5

Immedi-

ately

*3

Setup

*1

Pn819

4

Final Travel Distance for
Homing

-1073741823

to

1073741823

1

reference

unit

100

Immediately

Setup

*1

∗1.

For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands

(Manual No.: SIEP S800000 54).

∗3.

Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.

∗4.

The settings are updated only if the sending of the reference has been stopped (DEN is set to 1).

∗5.

The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use
Pn842.

∗6.

The set value of Pn844 is valid when the set value of Pn818 is 0. Software version 0023 or higher is required to use
Pn844.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

4th 3rd 2nd 1st

digit digit digit digit

n.

Software Limit Function

0

Forward

1

Reverse

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)