4.1 MECHATROLINK-

II

Communications Settings

4-3

4

Op

er

at

io

n

4.1

MECHATROLINK-

II

Communications Settings

This section describes the switch settings necessary for MECHATROLINK-II communications.

4.1.1

Setting Switches SW1 and SW2

The SW2 DIP switch is used to make the settings for MECHATROLINK-II communications.

The station address is set using the DIP switches (SW1, SW2).

(1) Settings for the SW2 DIP Switch

The following table shows the settings of the DIP switch (SW2).

OFF

ON

SW1 (factory settings)

1

2

3

4

OFF

ON

SW2 (factory settings)

1

2

3

4

M-

II

SW2

Function

Setting

Description

Factory setting

Pin 1 Sets the baud rate.

OFF

4 Mbps (MECHATROLINK-I)

ON

ON

10 Mbps (MECHATROLINK-II)

Pin 2 Sets the number of

transmission bytes.

OFF

17 bytes

ON

ON

32 bytes

Pin 3 Sets the station address.

OFF

Station address = 40H + SW1

OFF

ON

Station address = 50H + SW1

Pin 4 Reserved. (Do not change.)

OFF

OFF

• When connecting to a MECHATROLINK-I network, turn OFF pins 1 and 2.
• When using a MECHATROLINK-I network (Baud rate: 4 Mbps), the settings for the num-

ber of transmission bytes is disabled and the number of transmission bytes is always 17.