ProSoft Technology ICX30-HWC User Manual
Page 58

Ethernet/IP Support
ICX30-HWC ♦ Industrial Cellular Gateway
User Manual
3G Cellular (M2M)
Page 58 of 64
ProSoft Technology, Inc.
June 22, 2015
6.3.4 ICX30.IO
This array contains the Analog and Digital input values of the ICX30-HWC. This
array is updated by triggering the ICX30.CONTROL.Get_Digital_Analog_Input
tag.
Caution: The data in this array is overwritten on every re-trigger of the
ICX30.CONTROL.Get_Digital_Analog_Input tag.
ICX30.IO.
Value
Description
Analog_1
0 to 32767
Analog input 1 raw value
Analog_2
0 to 32767
Analog input 2 raw value
Digital_1
0 or 1
Digital input 1 raw value (when output 1=no current,
0=current flow)
Digital_2
0 or 1
Digital input 2 raw value (when output 1=no current,
0=current flow)
6.3.5 ICX30.GPS
This array contains the current ICX30-HWC GPS data. This array is updated by
triggering the ICX30.CONTROL.Get_GPS tag.
Caution: The data in this array is overwritten on every re-trigger of the
ICX30.CONTROL.Get_GPS tag.
ICX30.GPS.
Value
Description
UTC_Time
Real
UTC Time in HHMMSS.x format. H=hour, M=minute,
S=second
Latitude
Real
Latitude in dddmm.mmmm format, d=degrees,
m=minutes
Longitude
Real
Longitude in dddmm.mmmm format, d= degrees,
m=minutes
Horiz_Dilution
Real
Horizontal Dilution of precision.
Altitude
Real
Altitude in meters above sea level.
GEOID_Height
SINT
Geoid Height in meters.
Last_Update_Interval
SINT
Time since last update.
Fix_Quality
SINT
GPS signal quality.
0 = Invalid
1 = Ideal
1 to 2 = Excellent
2 to 4 = Good
4 to 8 = Moderate
Satellite_Num
SINT
Number of Satellites in range.