beautypg.com

Power requirements – ProSoft Technology ICX30-HWC User Manual

Page 11

background image

ICX30-HWC ♦ Industrial Cellular Gateway

Start Here

3G Cellular (M2M)

User Manual

ProSoft Technology, Inc.

Page 11 of 64

June 22, 2015

1.4

Power Requirements

The ICX30-HWC accepts voltages between 10 and 24 VDC (300 mA @ 12 VDC,
150 mA @ 24 VDC), with an average power draw of 6 watts or less. A
detachable power connector comes with the radio, as shown below. The
connector terminals are labeled + (positive DC connection) and - (DC ground
connection).

The AC-to-DC power supply adapter may be used. DC power wires must be less
than 2 meters in length to meet regulatory requirements.

Important: When wiring the power connector, be sure to observe the proper polarity markings on
the power connector. Improper connector wiring can cause serious damage to the ICX30-HWC

which will not be covered under the ProSoft Warranty.

The power connector (ProSoft P/N 002-0116) and wire installation tool (ProSoft
P/N 357-0061) are shown in the following graphic. The wire installation tool is
helpful when installing wires into the spring-loaded contacts inside the power
connector.

1 To use the wire installation tool, insert it into the connector as shown.

2 Press down on the installation tool to use it as a level which opens the

connector's contacts to insert a wire. A properly wired connector is shown.